Non-invasive determination of cardiac output in pre-capillary pulmonary hypertension

Articolo
Data di Pubblicazione:
2015
Abstract:
Background
Cardiac output (CO) is a major diagnostic and prognostic factor in pre-capillary pulmonary hypertension (PH). Reference methods for CO determination, like thermodilution (TD), require invasive procedures and allow only steady-state measurements. The Modelflow (MF) method is an appealing technique for this purpose as it allows non-invasive and beat-by- beat determination of CO.
Methods
We aimed to compare CO values obtained simultaneously from non-invasive pulse wave analysis by MF (COMF) and by TD (COTD) to determine its precision and accuracy in precapillary PH. The study was performed on 50 patients with pulmonary arterial hypertension (PAH) or chronic thrombo-embolic PH (CTEPH). CO was determined at rest in all patients (n = 50) and during nitric oxide vasoreactivity test, fluid challenge or exercise (n = 48).
Results
Baseline COMF and COTD were 6.18 ± 1.95 and 5.46 ± 1.95 L_min-1, respectively. Accuracy and precision were 0.72 and 1.04 L_min-1, respectively. Limits of agreement (LoA) ranged from -1.32 to 2.76 L_min-1. Percentage error (PE) was ±35.7%. Overall sensitivity and specificity of COMF for directional change were 95.2% and 82.4%, (n = 48) and 93.3% and 100% for directional changes during exercise (n = 16), respectively. After application of a correction factor (1.17 ± 0.25), neither proportional nor fixed bias was found for subsequent CO determination (n = 48). Accuracy was -0.03 L_min−1 and precision 0.61 L_min−1. LoA ranged from -1.23 to 1.17 L_min−1 and PE was ±19.8%.
Conclusions
After correction against a reference method, MF is precise and accurate enough to determine absolute values and beat-by-beat relative changes of CO in pre-capillary PH.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Medicine, Cardiovascular system
Elenco autori:
Lador, Frédéric; Hervé, Philippe; Bringard, Aurélien; Günther, Sven; Garcia, Gilles; Savale, Laurent; Ferretti, Guido; Soccal, Paola M.; Chemla, Denis; Humbert, Marc; Simonneau, Gérald; Sitbon, Olivier
Autori di Ateneo:
FERRETTI GUIDO
Link alla scheda completa:
https://iris.unibs.it/handle/11379/479882
Link al Full Text:
https://iris.unibs.it/retrieve/handle/11379/479882/40475/Lador%20PL1%202015.pdf
Pubblicato in:
PLOS ONE
Journal