Polychlorinated biphenyls in serum, liver and adipose tissue of subjects with hepatocellular carcinoma living in a high polluted area.
Articolo
Data di Pubblicazione:
2013
Abstract:
Brescia (North Italy) is located in a highly industrialized area with diffuse environmental pollution by
polychlorinated biphenyls (PCBs) and with a high incidence of hepatocellular carcinoma (HCC). We aimed
to investigate the concentration of PCBs congeners in serum, liver and adipose tissue of patients with HCC
living in this area.
We enrolled prospectively 101 HCC incident cases. Lipid-adjusted PCBs concentration of single congeners and total PCBs concentration, computed as the sum of 24 PCBs congeners, were measured in the
serum of all subjects and in the liver and abdominal fat of 59 HCC cases undergoing surgery.
A high correlation was found between PCBs serum and liver (Spearman r = 0.79), serum and fat
(r = 0.91), and liver and fat (r = 0.75) concentrations. Serum PCBs concentration in HCC patients did not
vary according to demographical, clinical or epidemiological variables, apart from age, as PCBs concentration increased linearly with the subject’s age. This study confirms that serum lipid-adjusted PCBs concentration is a valid measure of PCBs body storage and is highly correlated with PCBs concentration detected
in other biological samples.
polychlorinated biphenyls (PCBs) and with a high incidence of hepatocellular carcinoma (HCC). We aimed
to investigate the concentration of PCBs congeners in serum, liver and adipose tissue of patients with HCC
living in this area.
We enrolled prospectively 101 HCC incident cases. Lipid-adjusted PCBs concentration of single congeners and total PCBs concentration, computed as the sum of 24 PCBs congeners, were measured in the
serum of all subjects and in the liver and abdominal fat of 59 HCC cases undergoing surgery.
A high correlation was found between PCBs serum and liver (Spearman r = 0.79), serum and fat
(r = 0.91), and liver and fat (r = 0.75) concentrations. Serum PCBs concentration in HCC patients did not
vary according to demographical, clinical or epidemiological variables, apart from age, as PCBs concentration increased linearly with the subject’s age. This study confirms that serum lipid-adjusted PCBs concentration is a valid measure of PCBs body storage and is highly correlated with PCBs concentration detected
in other biological samples.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Zani, Claudia; Gelatti, Umberto; Donato, Francesco; Capelli, Michela; Portolani, Nazario; Bergonzi, R; Apostoli, Pietro
Link alla scheda completa:
Pubblicato in: