Skip to Main Content (Press Enter)

Logo UNIBS
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione

Competenze & Professionalità
Logo UNIBS

|

Competenze & Professionalità

unibs.it
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione
  1. Pubblicazioni

The plateau in the NIRS-derived [HHb] signal near the end of a ramp incremental test does not indicate the upper limit of O2 extraction in the vastus lateralis

Articolo
Data di Pubblicazione:
2017
Abstract:
This study aimed to examine, at the level of the active muscles, whether the plateau in oxygen (O2) extraction normally observed near the end of a ramp incremental (RI) exercise test to exhaustion is caused by the achievement of an upper limit in O2 extraction. Eleven healthy men (27.3 ± 3.0 yr, 81.6 ± 8.1 kg, 183.9 ± 6.3 cm) performed a RI cycling test to exhaustion. O2 extraction of the vastus lateralis (VL) was measured continuously throughout the test using the near-infrared spectroscopy (NIRS)-derived deoxygenated hemoglobin [HHb] signal. A leg blood flow occlusion was performed at rest (LBFOCC1) and immediately after the RI test (LBFOCC2). The [HHb] values during the resting occlusion (108.1 ± 21.7%; LBFOCC1) and the peak values during exercise (100 ± 0%; [HHb]plateau) were significantly greater than those observed at baseline (0.84 ± 10.6% at baseline 1 and 0 ± 0% at baseline 2) (P < 0.05). No significant difference was found between LBFOCC1 and [HHb]plateau (P > 0.05) or between the baseline measurements (P > 0.05). [HHb] values at LBFOCC2 (130.5 ± 19.7%) were significantly greater than all other time points (P < 0.05). These results support the existence of an O2 extraction reserve in the VL muscle at the end of a RI cycling test and suggest that the observed plateau in the [HHb] signal toward the end of a RI test is not representative of an upper limit in O2 extraction.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
blood flow; deoxygenated hemoglobin; muscle oxygen extraction
Elenco autori:
Inglis, Ec; Iannetta, D; Murias, Jm
Autori di Ateneo:
IANNETTA DANILO
Link alla scheda completa:
https://iris.unibs.it/handle/11379/605277
Pubblicato in:
AMERICAN JOURNAL OF PHYSIOLOGY. REGULATORY, INTEGRATIVE AND COMPARATIVE PHYSIOLOGY
Journal
  • Assistenza
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.6.0.0