Skip to Main Content (Press Enter)

Logo UNIBS
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione

Competenze & Professionalità
Logo UNIBS

|

Competenze & Professionalità

unibs.it
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione
  1. Pubblicazioni

Assessment of an IMU-Based Experimental Set-Up for Upper Limb Motion in Obese Subjects

Articolo
Data di Pubblicazione:
2023
Abstract:
In recent years, wearable systems based on inertial sensors opened new perspectives for functional motor assessment with respect to the gold standard motion capture systems. The aim of this study was to validate an experimental set-up based on 17 body-worn inertial sensors (Awinda, Xsens, The Netherlands), addressing specific body segments with respect to the state-of-the art system (VICON, Oxford Metrics Ltd., Oxford, UK) to assess upper limb kinematics in obese, with respect to healthy subjects. Twenty-three obese and thirty healthy weight individuals were simultaneously acquainted with the two systems across a set of three tasks for upper limbs (i.e., frontal arm rise, lateral arm rise, and reaching). Root Mean Square error (RMSE) was computed to quantify the differences between the measurements provided by the systems in terms of range of motion (ROM), whilst their agreement was assessed via Pearson's correlation coefficient (PCC) and Bland-Altman (BA) plots. In addition, the signal waveforms were compared via one-dimensional statistical parametrical mapping (SPM) based on a paired t-test and a two-way ANOVA was applied on ROMs. The overall results partially confirmed the correlation and the agreement between the two systems, reporting only a moderate correlation for shoulder principal rotation angle in each task (r similar to 0.40) and for elbow/flexion extension in obese subjects (r = 0.66), whilst no correlation was found for most non-principal rotation angles (r < 0.40). Across the performed tasks, an average RMSE of 34 degrees and 26 degrees was reported in obese and healthy controls, respectively. At the current state, the presence of bias limits the applicability of the inertial-based system in clinics; further research is intended in this context.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
IMU; functional assessment; obesity; upper limbs
Elenco autori:
Cerfoglio, S.; Lopomo, N. F.; Capodaglio, P.; Scalona, E.; Monfrini, R.; Verme, F.; Galli, M.; Cimolin, V.
Link alla scheda completa:
https://iris.unibs.it/handle/11379/591062
Pubblicato in:
SENSORS
Journal
  • Assistenza
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.5.1.0