Skip to Main Content (Press Enter)

Logo UNIBS
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione

Competenze & Professionalità
Logo UNIBS

|

Competenze & Professionalità

unibs.it
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione
  1. Pubblicazioni

Sutureless Valve in Repeated Aortic Valve Replacement: Results from an International Prospective Registry

Articolo
Data di Pubblicazione:
2021
Abstract:
Objective: To report early and midterm results registry of patients undergoing repeated aortic valve replacement (RAVR) with sutureless prostheses from an international prospective registry (SURE-AVR). Methods: Between March 2011 and June 2019, 69 patients underwent RAVR with self-expandable sutureless aortic bioprostheses at 22 international cardiac centers.Results: Overall mortality was 2.9% with a predicted logistic EuroSCORE 11 of 10.7%. Indications for RAVR were structural valve dysfunction (84.1%) and infective prosthetic endocarditis (15.9%) and were performed in patients with previously implanted bioprostheses (79.7%), mechanical valves (15.9%), and transcatheter valves (4.3%). Minimally invasive approach was performed in 15.9% of patients. Rate of stroke was 1.4% and rate of early valve-related reintervention was 1.4%. Overall survival rate at 1 and 5 years was 97% and 91%, respectively. No major paravalvular leak occurred. Rate of pacemaker implantation was 5.8% and 0.9% per patient-year early and at follow-up, respectively. The mean transvalvular gradient at 1-year and 5-year follow-up was 10.5 mmHg and 11.5 mmHg with a median effective orifice area of 1.8 cm 2 and 1.8 cm 2 , respectively. Conclusions: RAVR with sutureless valves is a safe and effective approach and provides excellent clinical and hemodynamic results up to 5 years.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
AVR; redo surgery; sutureless
Elenco autori:
Glauber, M.; Kent, W. D. T.; Asimakopoulos, G.; Troise, G.; Padro, J. M.; Royse, A.; Marnette, J. -M.; Noirhomme, P.; Baghai, M.; Lewis, M.; Di Bacco, L.; Solinas, M.; Miceli, A.
Link alla scheda completa:
https://iris.unibs.it/handle/11379/577672
Link al Full Text:
https://iris.unibs.it/retrieve/handle/11379/577672/196037/glauber-et-al-2021-sutureless-valve-in-repeated-aortic-valve-replacement-results-from-an-international-prospective.pdf
Pubblicato in:
INNOVATIONS
Journal
  • Assistenza
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.5.2.0