Transaxillary Tri-Branch Aortic Endovascular Graft Repair of Recurrent Thoracoabdominal Aneurysm With Pararenal Aortic Occlusion
Articolo
Data di Pubblicazione:
2022
Abstract:
The absence of an adequate ileo-femoral access is usually considered an absolute contraindication to fenestrated and branched aortic repairs. Alternative routes and dedicated stent-graft designs have been advocated. Hereby, we describe the case of a 73-year-old man with a recurrent type IV thoracoabdominal aortic aneurysm and complete thrombotic pararenal aortic occlusion treated successfully with a tri-branch custom-made endograft deployed via a transaxillary access.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
aortic aneurysm; aortic plug; axillary; branched stent-graft; extra-anatomical bypass; recurrent; thoracoabdominal aorta
Elenco autori:
Bertoglio, L.; Lopes, A.; Rinaldi, E.; Bossi, M.; Berchiolli, R.; Ferrari, M.; Chiesa, R.
Link alla scheda completa:
Pubblicato in: