Skip to Main Content (Press Enter)

Logo UNIBS
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione

Competenze & Professionalità
Logo UNIBS

|

Competenze & Professionalità

unibs.it
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione
  1. Pubblicazioni

A new interpolation-free procedure for breath-by-breath analysis of V’O2 in exercise transients

Articolo
Data di Pubblicazione:
2014
Abstract:
Introduction. Interpolation methods circumvent poor time resolution of breath-by-breath oxygen uptake (VO2) kinetics at exercise onset. We report an interpolation-free approach to the improvement of poor time resolution in the analysis of VO2 kinetics.
Methods. Noiseless and noisy (10% Gaussian noise) synthetic data were generated by Monte Carlo method from pre-selected parameters (Exact Parameters). Each data set comprised 10 O2-on transitions with noisy breath distribution within a physiological range. Transitions were superposed (no interpolation, None), then analysed by bi-exponential model. Fitted model parameters were compared with those from interpolation methods (average transition after Linear or Step 1-sec interpolations), applied on the same data. Experimental data during cycling were also analysed. The 95% confidence interval around a line of parameters’ equality was computed to analyse agreement between exact parameters and corresponding parameters of fitted functions.
Results. The line of parameters’ equality stayed within confidence intervals for noiseless synthetic parameters with None, unlike Step and Linear, indicating that None reproduced Exact Parameters. Noise addition reduced differences among pre-treatment procedures. Experimental data provided lower phase I time constants with None than with Step.
Conclusion. In conclusion, None revealed better precision and accuracy than Step and Linear, especially when phenomena characterized by time constants of less than 30 sec are to be analysed. Therefore, we endorse the utilization of None to improve the quality of breath-by-breath VO2 data during exercise transients, especially when a double exponential model is applied and phase I is accounted for.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Gas exchange; Humans; Kinetics; Procedure
Elenco autori:
Bringard, A.; Adami, A.; Moia, C.; Ferretti, Guido
Autori di Ateneo:
FERRETTI GUIDO
Link alla scheda completa:
https://iris.unibs.it/handle/11379/453223
Pubblicato in:
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY
Journal
  • Assistenza
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.5.2.0