Skip to Main Content (Press Enter)

Logo UNIBS
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione

Competenze & Professionalità
Logo UNIBS

|

Competenze & Professionalità

unibs.it
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione
  1. Pubblicazioni

Cardiac implantable electronic devices with a defibrillator component and all-cause mortality in left ventricular assist device carriers: results from the PCHF-VAD registry

Articolo
Data di Pubblicazione:
2019
Abstract:
Aims: To compare characteristics of left ventricular assist device (LVAD) recipients receiving a cardiac implantable electronic device (CIED) with a defibrillator component (implantable cardioverter-defibrillator and cardiac resynchronization therapy with defibrillation, CIED-D) vs. those without one, and to assess whether carrying such a device contiguously with an LVAD is associated with outcomes. Methods and results: Overall, 448 patients were analysed (mean age 52 ± 13 years, 82% male) in the multicentre European PCHF-VAD registry. To account for all active CIED-Ds during ongoing LVAD treatment, outcome analyses were performed by a time-varying analysis with active CIED-D status post-LVAD as the time-varying covariate. At the time of LVAD implantation, 235 patients (52%) had an active CIED-D. Median time on LVAD support was 1.1 years (interquartile range 0.5–2.0 years). A reduction of 36% in the risk of all-cause mortality was observed in patients with an active CIED-D [hazard ratio (HR) 0.64, 95% confidence interval (CI) 0.46–0.91; P = 0.012), increasing to 41% after. adjustment for baseline covariates (HR 0.59, 95% CI 0.40–0.87; P = 0.008) and 39% after propensity score adjustment (HR 0.61, 95% CI 0.39–0.94; P = 0.027). Other than CIED-D, age, LVAD implant as redo surgery, number of ventricular arrhythmia episodes and use of vasopressors pre-LVAD were remaining significant risk factors of all-cause mortality. Incident ventricular arrhythmias post-LVAD portended a 2.4-fold and 2.6-fold increased risk of all-cause and cardiovascular death, respectively; carrying an active CIED-D remained associated with a 47% and 43% reduction in these events, respectively. Conclusions: In an analysis accounting for all active CIED-Ds, including those implanted during LVAD support, carrying such a device was associated with significantly better survival during LVAD support.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Advanced heart failure; Cardiac implantable electronic device; Cardiac resynchronization therapy; Implantable cardioverter-defibrillators; Left ventricular assist devices; Mortality; Ventricular arrhythmia
Elenco autori:
Cikes, M.; Jakus, N.; Claggett, B.; Brugts, J. J.; Timmermans, P.; Pouleur, A. -C.; Rubis, P.; Van Craenenbroeck, E. M.; Gaizauskas, E.; Grundmann, S.; Paolillo, S.; Barge-Caballero, E.; D'Amario, D.; Gkouziouta, A.; Planinc, I.; Veenis, J. F.; Jacquet, L. -M.; Houard, L.; Holcman, K.; Gigase, A.; Rega, F.; Rucinskas, K.; Adamopoulos, S.; Agostoni, P.; Biocina, B.; Gasparovic, H.; Lund, L. H.; Flammer, A. J.; Metra, M.; Milicic, D.; Ruschitzka, F.
Link alla scheda completa:
https://iris.unibs.it/handle/11379/532143
Pubblicato in:
EUROPEAN JOURNAL OF HEART FAILURE
Journal
  • Assistenza
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.4.5.0