e-DoIT-RISE - echo-Doppler Imaging Tonometer: Reference Infrastructure for Stiffness Evaluation

Project
e-DoIT-RISE (echo-Doppler Imaging Tonometer – Reference Infrastructure for Stiffness Evaluation) aims to develop and validate a non-clinical, in vitro metrological infrastructure for local/segmental Pulse Wave Velocity (PWV) measurement using conventional ultrasound systems equipped with Color Doppler Imaging (US-CDI). PWV is a physical quantity related to pulse-wave propagation and widely used as a biomarker of arterial stiffness and cardiovascular risk. Current non-invasive approaches are mostly regional and affected by pulse-path uncertainty, waveform distortion, reflected waves, motion artefacts, operator dependence and Pulse Transit Time (PTT) estimation. Local PWV assessment with conventional clinical ultrasound is limited by spatial resolution and frame rate. The project builds on the patented e-DOT/e-DoIT concept and on preliminary evidence that equivalent-time post-processing of Color Doppler videos can estimate PTT and derive flow or pulse-wave velocities in controlled test objects and arterial simulators. The project will integrate ETIMAS, the Equivalent Time-based Image Analysis Software implementing the US-CDI video-to-PWV pipeline at the core of e-DoIT, with an Instrumented Arterial Simulator (IAS) acting as the in vitro metrological reference system. The IAS will include arterial test objects acting as ultrasound phantoms, mimicking materials, controlled pressure/flow and transmural-pressure conditions, IAS-generated synchronization signals, auxiliary sensors for pressure, flow, displacement/deformation and timing, and repeatable IAS/RISE bench configurations. Functional qualification protocols and acceptance criteria will assess the suitability of the Color Doppler mode for PWV measurement. The work plan includes definition of the PWV measurand and US-CDI/ETIMAS model; robustness assessment of the ETIMAS equivalent-time PTT estimation step; design and development of IAS and arterial test objects; integration of sensor data, metadata, quality indicators, uncertainty budgets, ETIMAS versioning and traceability logs into RISE; Color Doppler qualification; and non-clinical validation through repeatable in vitro campaigns. Metrological traceability will be pursued through a documented reference chain based on IAS settings, calibrated or verified auxiliary sensors, uncertainty evaluation of distance and PTT estimates, and functional qualification of the US-CDI acquisition chain. No tests on patients, volunteers or biological samples are planned, and no personal health data will be processed. The expected outcome is a reference infrastructure enabling robust and reproducible in vitro PWV measurements with documented uncertainty, quality indicators and traceability, allowing meaningful comparison across IAS conditions, US-CDI configurations, processing pipelines and validation campaigns, and providing the metrological basis for future quality-assured ultrasound-based tools for vascular stiffness assessment and cardiovascular prevention.
  • Overview
  • Research

Overview

Contributor

LANCINI MATTEO   Scientific Manager  

Leading department

Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health   Principale  

Term type

Progetto PRIN 2026 - PRIN bando 2026

Financier

MUR-MINISTERO DELL'UNIVERSITA' E DELLA RICERCA

Leader

Università degli Studi ROMA TRE

Partner (3)

Università degli Studi di CATANIA
Università degli Studi Niccolò Cusano - Telematica Roma
Università degli Studi di BRESCIA

Date/time interval

January 20, 2027 - January 20, 2030

Project duration

36 months

Research

Concepts (3)


PE7_11 - Components and systems for applications (in e.g. medicine, biology, environment) - (2024)

Goal 3: Good health and well-being

Settore IMIS-01/A - Misure meccaniche e termiche

Free text keywords (6)

  • ascendant
  • decrescent
Arterial Simulator
Biomedical Metrology
Color Doppler Imaging
Measurement Uncertainty
Pulse Wave Velocity
Traceability