Biological monitoring of exposure to low concentrations of benzene in workers at a metallurgical coke production plant: new insights into S-phenylmercapturic acid and urinary benzene
Articolo
Data di Pubblicazione:
2017
Abstract:
Context: Urinary S-phenylmercapturic acid (SPMA) and benzene (U-Ben) are usually measured at the end of the work shift (ES), although their kinetic of elimination is not clearly known. Objective: To investigate SPMA and U-Ben elimination 16 h after the ES, in 93 coke production workers exposed to low benzene concentrations. Materials and methods: Airborne benzene (A-Ben) was measured by passive samplings, while SPMA,
U-Ben, methyl-tert-butyl ether (U-MTBE), cotinine (U-Cot) and creatinine were determined on urine samples collected at ES and before the beginning of the next work shift (next BS). Results: Median A-Ben concentrations were 17.2 mg/m3 in the personal and 34.7 mg/m3 in the stationary samplings. SPMA was always detectable, whereas U-Ben was below the limit of quantification in 26.7% of the ES and 35.6% of the next BS samples, and U-MTBE in more than the 80.0% of the samples. At both the sampling times, SPMA and U-Ben showed a positive dependence on personal A-Ben, as well as on creatinine and U-Cot values. Discussion and conclusion: SPMA and U-Ben at the next BS were dependent on the exposure to low benzene concentrations suffered in the previous work shift, prompting a reconsideration of the urine sampling time recommended by the American Conference Governmental Industrial Hygienists (ACGIH).
U-Ben, methyl-tert-butyl ether (U-MTBE), cotinine (U-Cot) and creatinine were determined on urine samples collected at ES and before the beginning of the next work shift (next BS). Results: Median A-Ben concentrations were 17.2 mg/m3 in the personal and 34.7 mg/m3 in the stationary samplings. SPMA was always detectable, whereas U-Ben was below the limit of quantification in 26.7% of the ES and 35.6% of the next BS samples, and U-MTBE in more than the 80.0% of the samples. At both the sampling times, SPMA and U-Ben showed a positive dependence on personal A-Ben, as well as on creatinine and U-Cot values. Discussion and conclusion: SPMA and U-Ben at the next BS were dependent on the exposure to low benzene concentrations suffered in the previous work shift, prompting a reconsideration of the urine sampling time recommended by the American Conference Governmental Industrial Hygienists (ACGIH).
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
SPMA; urinary benzene; coke production; biological monitoring; benzene
Elenco autori:
Lovreglio, Piero; DE PALMA, Giuseppe; Barbieri, Anna; Andreoli, Roberta; Drago, Ignazio; Greco, Luciano; Gallo, Elisabetta; Diomede, Laura; Scaramuzzo, Pietro; Ricossa, Maria Cristina; Fostinelli, Jacopo; Apostoli, Pietro; Soleo, Leonardo
Link alla scheda completa:
Pubblicato in: