Skip to Main Content (Press Enter)

Logo UNIBS
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione

Competenze & Professionalità
Logo UNIBS

|

Competenze & Professionalità

unibs.it
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione
  1. Pubblicazioni

Clinical analysis of macular edema with new software for SD-OCT imaging

Articolo
Data di Pubblicazione:
2013
Abstract:
Purpose: To evaluate the clinical efficacy of user-friendly software for the measurement of intraretinal hyporeflective spaces expression of macular edema.
Methods: Fifteen consecutive patients with diabetic retinopathy with clinically significant macular edema were examined using conventional spectral domain optical coherence tomography (OCT). A new composite software application, OCT-measurement analysis tool (OCT-MAT), was developed to automatically process and analyze OCT B-scans by means of image acquisition, filtering, and elaboration, together with hyporeflective area recognition and measurement in µm. The same macular areas were measured manually, and then compared to the measurements obtained by the automated OCT-MAT software. A statistical test analysis was applied (statistical significance level at p<0.05). The repeatability and reproducibility coefficient for the automated software was computed using the Wilcoxon matched pair test (5% significance level).
Results: In all patients, the software effectively measured the number and extension of intraretinal hyporeflective spaces in µm. The comparison between mean manual measurements and OCT-MAT measurements (0.478 ± 0.300 × 10 vs 0.471 ± 0.321 × 10 µm) showed correct correspondence . Moreover, the OCT-MAT software showed good repeatability and reproducibility (coefficient below 3%).
Conclusions: OCT-MAT allows the precise measurement of macular edema in terms of the number of empty spaces and their size in all patients. Its daily clinical application might give precise information regarding the evolution of macular edema and the efficacy of therapy.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
macular edema; SD-OCT; measurement software
Elenco autori:
Azzolini, C; Sansoni, Giovanna; Donati, S; Parodi, Mb; Al Oum, M; Vinciguerra, R; Tartaglia, V; Semeraro, Francesco; Virgili, G.
Autori di Ateneo:
SEMERARO FRANCESCO
Link alla scheda completa:
https://iris.unibs.it/handle/11379/264107
Pubblicato in:
EUROPEAN JOURNAL OF OPHTHALMOLOGY
Journal
  • Assistenza
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.5.1.0