Skip to Main Content (Press Enter)

Logo UNIBS
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione

Competenze & Professionalità
Logo UNIBS

|

Competenze & Professionalità

unibs.it
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione
  1. Pubblicazioni

Efficacy of Sutureless Scleral Fixation of One-Piece T-Shaped Haptic Intraocular Lens in Maintaining Anterior Chamber Stability During Descemet Membrane Endothelial Keratoplasty in Vitrectomized Eyes: Leak Test and Iris Diaphragm Reconstruction

Articolo
Data di Pubblicazione:
2024
Abstract:
Objectives: This study aimed to describe the outcomes of a staged procedure combining Descemet membrane endothelial keratoplasty (DMEK) and sutureless scleral fixation (SSF) of a one-piece intraocular lens (IOL) in a case series. Co-performing endothelial keratoplasty (EK) and SSF is associated with intraoperative and postoperative complications such as graft deployment difficulties, air migration, graft detachment, and IOL opacification or tilt, all of which are evaluated in this study. Methods: This is a retrospective observational case series. Clinical data were collected from eight eyes of eight patients who underwent DMEK for endothelial failure and had previously received an SSF with one-piece IOL following complete vitrectomy. During DMEK surgery, an air leak test was conducted to check for air migration into the posterior chamber. If instability was detected, pupilloplasty was performed. Intraoperative and postoperative data, including DMEK graft unfolding time, were collected. Corrected Distance Visual Acuity (CDVA), refraction, endothelial cell density (ECD), central corneal thickness (CCT), intraocular pressure (IOP), and complications were recorded over a 12-month follow-up period. Results: We performed pupilloplasty in four patients (50%). The median CDVA improved from preoperative 0.85 logMAR (range: 0.60 to 1.00) at baseline to 0.18 logMAR (range: 0.10 to 0.70, p = 0.012) at 12 months. The median refraction value changed significantly from −1.00 to −0.50 at 12 months. The median percentage reduction in ECD after 12 months was 33.4% (range 30 to 40). The median baseline CCT was 689 μm (range: 651 to 701) at baseline visit and 541.5 μm (range: 525 to 591, p = 0.008) at 12 months. The median IOP was reduced significantly during follow-up. The median graft unfolding time was 6 min (5 to 9). One patient required rebubbling for partial detachment on postoperative day one. No complications occurred within 12 months. Conclusions: The effective compartmentalization of the anterior and posterior chambers in vitrectomized eyes with an SSF one-piece IOL and pupilloplasty can facilitate critical steps of DMEK surgery in complex eyes. Additionally, the air leak test could prove useful in identifying the need for iris-lens diaphragm reconstruction.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
complication; DMEK surgery; graft detachment; graft dislocation; IOL damage; IOL opacification; scleral lens fixation
Elenco autori:
Vaiano, A. S.; Greco, A.; Marenco, M.; Greco, A.; De Filippis, A.; Garavelli, F.; Merli, R.; Romano, V.
Autori di Ateneo:
ROMANO VITO
Link alla scheda completa:
https://iris.unibs.it/handle/11379/634315
Pubblicato in:
JOURNAL OF CLINICAL MEDICINE
Journal
  • Assistenza
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.5.1.0