Skip to Main Content (Press Enter)

Logo UNIBS
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione

Competenze & Professionalità
Logo UNIBS

|

Competenze & Professionalità

unibs.it
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione
  1. Pubblicazioni

Transoral laser microsurgery: feasibility of a new exoscopic HD-3D system coupled with free beam or fiber laser

Articolo
Data di Pubblicazione:
2021
Abstract:
In the last decades, new technological devices and instruments have been developed to overcome the technical limits of transoral laser microsurgery. The recent introduction of 3D endoscopy seems to be a promising tool in the field of diagnostic and operative laryngology as an alternative to the traditional microlaryngoscopy. Our work aims to present a novel transoral microsurgical setting that expands the use of exoscopic systems (in this case the VITOM® 3D-HD) as an alternative to the standard operating microscope. A customized support arm and an adaptor to firmly connect the VITOM® 3D-HD camera to the laser micromanipulator were specially designed. This setup was used as an alternative to the standard operating microscope in a cohort of 17 patients affected by suspicious early to intermediate pharyngo-laryngeal neoplasms. A historical cohort of patients treated with the traditional setting and matching the same inclusion criteria was used as a reference for the duration of surgical procedures. The surgical procedures comprised 7 cordectomies, 2 endoscopic partial supraglottic laryngectomies, 4 tongue base resections, and 4 lateral oropharyngectomies or hypopharyngectomies. In 6 cases (35%), a simultaneous neck dissection was performed. The low rate of positive deep (6%) or superficial (12%) margins reinforced the safety of this platform, and the results obtained in terms of operating time were comparable to the control group (p > 0.05), which confirms the feasibility of the system. Our surgical setting setup is a convincing alternative to traditional transoral laser microsurgery for early to intermediate pharyngo-laryngeal neoplasms. The main advantages of this system are comfortable ergonomics for the first surgeon and a potential benefit in terms of teaching if applied in university hospitals, since the entire surgical team can view the same surgical 3D-HD view of the first operator. Further work is still needed to objectively compare the traditional and new technique, and to validate our preliminary clinical findings.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
CO2 laser; Exoscope; Laryngeal cancer; Oropharyngeal cancer; TLM; TOLMS; Vitom 3D; Feasibility Studies; Humans; Lasers; Microsurgery; Retrospective Studies; Laryngeal Neoplasms; Laser Therapy
Elenco autori:
Carobbio, A. L. C.; Missale, F.; Fragale, M.; Mora, F.; Guastini, L.; Parrinello, G.; Canevari, F. R. M.; Peretti, G.; Mattos, L. S.
Link alla scheda completa:
https://iris.unibs.it/handle/11379/551527
Pubblicato in:
LASERS IN MEDICAL SCIENCE
Journal
  • Assistenza
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.5.2.0