Skip to Main Content (Press Enter)

Logo UNIBS
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione

Competenze & Professionalità
Logo UNIBS

|

Competenze & Professionalità

unibs.it
  • ×
  • Home
  • Persone
  • Strutture
  • Competenze
  • Pubblicazioni
  • Professioni
  • Corsi
  • Insegnamenti
  • Terza Missione
  1. Pubblicazioni

Outcome of Descemet stripping automated endothelial keratoplasty in eyes with an Ahmed glaucoma valve

Articolo
Data di Pubblicazione:
2017
Abstract:
Purpose: The purpose was to investigate the survival of Descemet stripping automated endothelial keratoplasty (DSAEK) in eyes with an Ahmed glaucoma valve (AGV). Methods: The study had a retrospective case-series of patients with an AGV in the anterior chamber undergoing a DSAEK. Included in the analysis were graft size, number of previous operations, post-operative glaucoma medications, post-operative intraocular pressure (IOP) control, graft size and donor factors (age, endothelial cell density, and post-mortem time). A generalised linear model with binary logistic regression was used to test for an effect on graft survival at 1 year and 1.5 years. Results: Fourteen eyes from 13 patients were included. The survival rate of the first DSAEK at 6, 12, 18, 24 and 30-months was 85%, 71%, 50%, 36% and 30%, respectively. The mean duration to graft failure was 12.9 ± 6.2 months. Five of the seven failed first grafts went on to have a repeat DSAEK. The mean follow-up in this subgroup was 30.7 ± 18.4 months. The survival rate of second DSAEK at 6, 12, 18 and 24 months was 100% (5/5), 100% (5/5), 75% (3/4) and 67% (2/3). Only one second DSAEK failed in the duration of the study and went on to receive a third DSAEK which failed at 18-months. The mean IOP within the first year was significantly lower for grafts that survived at 1 and 1.5 years (17.4 mmHg, 16.9 mmHg) than for grafts that failed (19.4 mmHg, 19.4 mmHg) (p = 0.04, p = 0.009). Conclusion: DSAEK is a viable alternative to PK to restore visual function in eyes with an AGV sited in the anterior chamber. IOP is an important risk factor for graft failure.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
AGV; Ahmed glaucoma valve; Descemet stripping automated endothelial keratoplasty; DSAEK; Endothelial keratoplasty; Glaucoma drainage device; Graft survival
Elenco autori:
Chiam, P. J.; Cheeseman, R.; Ho, V. W.; Romano, V.; Choudhary, A.; Batterbury, M.; Kaye, S. B.; Willoughby, C. E.
Autori di Ateneo:
ROMANO VITO
Link alla scheda completa:
https://iris.unibs.it/handle/11379/555331
Pubblicato in:
GRAEFE'S ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
Journal
  • Assistenza
  • Privacy
  • Utilizzo dei cookie
  • Note legali

Realizzato con VIVO | Designed by Cineca | 26.6.0.0