Skip to Main Content (Press Enter)

Logo UNIBS
  • ×
  • Home
  • People
  • Organizations
  • Expertise & Skills
  • Outputs
  • Jobs
  • Degrees
  • Courses
  • Third Mission
  • Equipment

Expertise & Skills
Logo UNIBS

|

Expertise & Skills

unibs.it
  • ×
  • Home
  • People
  • Organizations
  • Expertise & Skills
  • Outputs
  • Jobs
  • Degrees
  • Courses
  • Third Mission
  • Equipment
  1. Outputs

Quality assessment of fetal middle cerebral and umbilical artery Doppler images using an objective scale within an international randomized controlled trial

Academic Article
Publication Date:
2020
Abstract:
Objectives: To determine the quality of Doppler images of the fetal middle cerebral artery (MCA) and umbilical artery (UA) using an objective scale, and to determine the reliability of this scale, within a multicenter randomized controlled trial (Revealed versus concealed criteria for placental insufficiency in unselected obstetric population in late pregnancy (Ratio37)). Methods: The Ratio37 trial is an ongoing randomized, open-label, multicenter controlled study of women with a low-risk pregnancy recruited at 20 weeks. Doppler measurements of the fetal MCA and UA were performed at 37 weeks. Twenty patients from each of the six participating centers were selected randomly, with two images evaluated per patient (one each for the MCA and UA). The quality of a total of 240 images was evaluated by six experts, scored on an objective scale of six items. Inter- and intrarater reliability was assessed using the Fleiss-modified kappa statistic for ordinal scales. Results: On average, 89.2% of MCA images and 85.0% of UA images were rated as being of perfect (score of 6) or almost perfect (score of 5) quality. Kappa values for intrarater reliability of quality assessment were 0.90 (95% CI, 0.88–0.92) and 0.90 (95% CI, 0.88–0.93) for the MCA and UA, respectively. The corresponding inter-rater reliability values were 0.85 (95% CI, 0.81–0.89) and 0.84 (95% CI, 0.80–0.89), respectively. Conclusion: The quality of MCA and UA Doppler ultrasound images can be evaluated reliably using an objective scale. Over 85% of images, which were obtained by operators from a broad range of clinical practices within a multicenter study, were rated as being of perfect or almost perfect quality. Intra- and inter-rater reliability of quality assessment was very good. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
CRIS type:
1.1 Articolo in rivista
Keywords:
Doppler; middle cerebral artery; quality control; randomized multicenter trial; reliability; umbilical artery
List of contributors:
Rial-Crestelo, M.; Morales-Rosello, J.; Hernandez-Andrade, E.; Prefumo, F.; Oros, D.; Caffici, D.; Sotiriadis, A.; Zohav, E.; Cruz-Martinez, R.; Parra-Cordero, M.; Lubusky, M.; Kacerovsky, M.; Figueras, F.
Authors of the University:
PREFUMO FEDERICO
Handle:
https://iris.unibs.it/handle/11379/536203
Published in:
ULTRASOUND IN OBSTETRICS & GYNECOLOGY
Journal
  • Support
  • Privacy
  • Use of cookies
  • Legal notes

Powered by VIVO | Designed by Cineca | 26.11.1.0